PROPERTY CONDITION REPORT

 

 CLIENT:

Smart Investor

 INSPECTION
 ADDRESS:

6 Unit Property
Kansas City MO 64137

 AGENT:

Great Agent

 DATE:

5/11/2021

 INSPECTOR:

Steve Rodriguez

 REPORT #:

20170605-6-unit-property

Acceptance of this home inspection report represents acknowledgement that it does not constitute a warranty, guarantee or insurance policy of any kind. There are no assurances made against future roof leaks, wet basements, or mechanical breakdowns. This report is a professional opinion based on a visual inspection of the accessible areas and features of the property as of the date and time of the inspection and is not a list of repairs to be made. The report is not an assessment nor is it an appraisal. Neither the inspector, nor Bulldog Professional Inspection Services (Bulldog) is associated with any seller, buyer, contractor, lawyer, or real estate professional. Other than the inspection fee, inspector has no financial interest in the property. This report is not transferable to third parties and both Bulldog and its employees are limited in liability to the fee paid for the inspection services and report.


     

www.BulldogInspect.com

 

 
5/11/2021 
 
Report# 20170605-6-unit-property 
 
6 Unit Property
Kansas City MO 64137
 
Hi Smart, 
 

Thank you for choosing Bulldog Professional Inspection Services.  I hope you found the experience both educational and insightful.

 

Let us know if you have any questions after reading your report.

 

We'll follow up in a few days to make sure you received it without trouble and have no last-minute questions. 

 

It was our pleasure serving you and congratulations on your new home! 

 
Your summaries and report follow below.
 
Steve Rodriguez
President and Certified Master Inspector
Bulldog Professional Inspection Services




Top Table of Contents Bottom

Table of Contents

Top Table of Contents Bottom

Safety Item Summary


Client
Smart Investor

Property Address
6 Unit Property
Kansas City MO 64137

2.  EXTERIOR COMPONENTS
2.4  EXTERIOR DOORS  
Safety Item.
11260/11258/11266 - Patio has big step into home.  Maximum height should be 8" (step is currently 12" high).  Recommend adding intermediate step to avoid associated tripping hazard.
2.4 Item 1(Picture) - Large step into 11260
2.4 Item 2(Picture) - Large step into 11258
2.4 Item 3(Picture) - Large step into 11266

6.  ROOMS
6.9  SMOKE DETECTOR  
Safety Item.
11262/11266/11264/11260 - Smoke detectors missing in ALL bedrooms.   Installation necessary to provide necessary early fire/smoke detection to spaces.

8.  COMMON AREAS
8.8  SMOKE/CO DETECTORS  
Safety Item.
11258/11256 - Smoke detector missing in upstairs hallway.   Installation necessary to provide necessary early fire/smoke detection to space.

9.  KITCHEN AND COMPONENTS
9.7  RECEPTACLES AND SWITCHES  
Safety Item.
11264/11260/11256 - No GFCI protection to the left of sink.  Recommend installing to provide necessary electrical safety protection to circuit. 

12.  BASEMENT/CRAWLSPACE/SUB-BASEMENT
12.0  BASEMENT STAIRWAY AND RAILING  
Safety Item.
11264 - Missing handrail at basement steps.  Recommend installing to provide necessary stability during use. 
12.0 Item 1(Picture) - Missing handrail at 11264 basement steps
12.12  SMOKE / CO DETECTORS  
Safety Item.
11256 - Smoke detector missing.   Installation necessary to provide necessary early fire/smoke detection to space.

14.  CENTRAL HEATING
14.4  CHIMNEYS, FLUES AND VENTS  
Maintenance Item.
(3) 11266 - Open seams at HVAC exhaust vent above furnace.  This is a health hazard since dangerous flue gases can escape into home. Recommend properly sealing all open seams with metal tape to maximize draw and maintain safe furnace operation. 
14.4 Item 3(Picture) - Open seams at 11266 furnace exhaust vent
14.7  SMOKE/CO DETECTORS IN SPACE  
Safety Item.
11262/11266/11264/11260/11258/11256 - No CO detector present in rooms with fuel burning appliances.  A CO detector should be installed in same space as all fuel-burning appliances (not directly above or beside units since it is normal for them to emit a small amount of carbon monoxide upon start-up) and in all upper-level hallways.   Recommend installing to provide early CO detection to occupants and avoid associated personal safety hazards


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Steve Rodriguez

Top Table of Contents Bottom

Major Item Summary


Client
Smart Investor

Property Address
6 Unit Property
Kansas City MO 64137

The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

3.  CENTRAL COOLING
3.0  COMPRESSOR UNIT  
Specialist Item.
(1) 11256/11262/11264/11266 - Outdoor unit is not level.  Excessive movement can crack HP/LP tubing at connections.  Unit works as intended during time of inspection, but recommend bringing unit to within 1 inch of level to maintain proper performance.
3.0 Item 1(Picture) - 11256 condenser unit not level
3.0 Item 2(Picture) - 11262 condenser not level
3.0 Item 3(Picture) - 11264 condenser is not level
3.0 Item 4(Picture) - 11266 A/C condenser is not level
(4) 11262/11264 - Broken electrical conduit at condenser unit.  This makes wiring vulnerable to inadvertent damage.  Recommend contracting professional HVAC technician to repair to maintain associate safe and proper performance.  Unit operates properly during time of inspection.
3.0 Item 7(Picture) - Broken conduit at 11262 A/C
3.0 Item 8(Picture) - Broken conduit at 11264 A/C unit
(6) 11264 - Damaged fins at exterior condenser unit.  Recommend contracting licensed HVAC technician to repair to maintain proper condenser performance.  Unit operates properly during time of inspection.
3.0 Item 9(Picture) - Dirty fins at 11264 condenser unit
3.1  REFRIGERANT LINES  
Specialist Item.
(1) 11258 - A/C refrigerant lines have iced up at condenser.  This is often caused by low refrigerant, a clogged filter, or a clogged evaporator coil.  Recommend contracting professional HVAC contractor to evaluate and repair to maintain proper system performance.  A/C is blowing warm during time of inspection.
3.1 Item 1(Picture) - Refrigerant lines have iced up
3.2  EVAPORATOR UNIT  
Specialist Item.
(1) 11258 - Evaporator is actively leaking behind furnace enclosure.  This is often caused by cracked pan or clogged drain.  If left unattended, this condition may ultimately crack the heat exchanger and cause premature furnace replacement.  Recommend contracting licensed HVAC technician to repair to maximize remaining life and system performance.  No significant damages visible during time of inspection.
3.2 Item 1(Picture) - 11258 evaporator is leaking behind furnace
(2) 11256 - Evaporator is actively leaking on top of furnace enclosure.  This is often caused by cracked pan or clogged drain.  If left unattended, this condition may ultimately crack the heat exchanger and cause premature furnace replacement.  Recommend contracting licensed HVAC technician to repair to maximize remaining life and system performance.  No significant damages visible during time of inspection.
3.2 Item 2(Picture) - Evaporator leakage on top of 11256

7.  BATHROOM
7.6  LIGHTING  
Specialist Item.
(1) 11262/11260 - Lighting is on GFCI circuit in main floor half bath.  This is improper since lights will not work if GFCI circuit is tripped.  Recommend contracting professional electrician to place lights on dedicated circuit to maintain constant, reliable function.

9.  KITCHEN AND COMPONENTS
9.2  CEILING  
Specialist Item.
11262 - Moisture stains and damages visible at ceiling.  This appears to be caused from active leakage at toilet in hall bath, above.  Recommend hiring professional roofing contractor to investigate and repair to avoid continued moisture damages.  Unable to determine extent of underlying damages during time of inspection.
9.2 Item 1(Picture) - Active leakage in 11262 kitchen ceiling

12.  BASEMENT/CRAWLSPACE/SUB-BASEMENT
12.2  FOUNDATION / WALLS  
Specialist Item.
(1) 11266 - Settlement cracking visible on East side of basement.  Previous repairs do not appear to have been successful since subsequent movement is visible.  Recommend hiring professional foundation contractor to properly repoint to avoid further deterioration and possible moisture seepage.  None visible during time of inspection.
12.2 Item 1(Picture) - Settlement crack in 11266 foundation wall
12.3  CEILING / SUB-FLOOR  
Specialist Item.
(1) 11260 - Moisture damages visible at sub-floor beneath half bath toilet.  Recommend hiring professional contractor to evaluate and repair to avoid further leakage and associated damages.  No significant damages visible during time of inspection.
12.3 Item 1(Picture) - Active leakage beneath 11260 half bath toilet
(2) 11260 - Daylight visible through sub floor on South side of basement.  Recommend hiring professional contractor to investigate and repair to avoid continued damage to underlying framing members.  No significant damages visible during time of inspection. 
12.3 Item 2(Picture) - Daylight through 11260 rim joist

14.  CENTRAL HEATING
14.1  HEATING EQUIPMENT  
Maintenance Item.
(2) 11258 - Furnace is 37 years old (expected life is 20-25 years) and displays heavy rust, corrosion, and sediment build-up in burner/blower/heat exchanger areas.  Unable to determine extent of underlying damages, but unit performs as intended during time of inspection.  Recommend having unit serviced regularly to maximize life and system efficiency.  Budget for future replacement.
14.1 Item 4(Picture) - View inside 11258 furnace

15.  PLUMBING SYSTEM
15.0  MAIN WATER SUPPLY  
Specialist Item.
11256 - Active leakage in pressure reducing valve.  Recommend contracting plumber to evaluate and repair to avoid continued leakage and possible moisture damage.  None visible during time of inspection.
15.0 Item 1(Picture) - Active leak at 11256 pressure reducing valve
15.3  DISTRIBUTION PIPING  
Specialist Item.
11262 - Copper plumbing is in contact with galvanized HVAC ducting.  This will lead to galvanic corrosion and leakage. Recommend contracting professional plumber to evaluate and relocate to avoid possible moisture damages.  None visible during time of inspection.
15.3 Item 1(Picture) - Water lines touch galvanized ducting in 11262 basement
15.5  FUEL DISTRIBUTION SYSTEMS  
Specialist Item.
11260 - No dirt leg present on natural gas supply line to water heater.  This is piping component is necessary to keep natural gas clean and extend life of associated gas appliances.  Recommend installing to maximize useful life.  See attached photo at bottom of report for a detailed view.
15.5 Item 1(Picture) - No dirt leg at 11260 water heater
15.6  WATER HEATER  
Maintenance Item.
(3) 11262 - Glass view port is broken.  This will affect water heater efficiency and performance.  Recommend hiring professional plumber to evaluate and repair to restore safe and proper operation.
15.6 Item 8(Picture) - Broken glass at 11262 water heater

16.  ELECTRICAL SYSTEMS
16.0  SERVICE ENTRANCE  
Specialist Item.
11256/11260 - Electrical service meter is pulling away from home.  This is likely caused by grading settlement. Recommend contract local utility to properly evaluate and repair to maintain reliable service and avoid possible damage.  No significant damages visible during time of inspection.
16.0 Item 1(Picture) - Loose meter at 11256
16.0 Item 2(Picture) - Loose meter at 11260
16.1  DISTRIBUTION PANEL  
Maintenance Item.
(2) 11262 - 15-Amp circuit breaker in main panel would not reset (unable to turn breaker on) during time of inspection.  Recommend contracting electrician to investigate and repair to restore proper operation.  Unable to pinpoint cause during time of inspection.
16.1 Item 2(Picture) - Breaker will not reset in 11262 panel
(4) 11264/11256 - Double tapping present (2 circuits double tapped).  This presents a possible overheating hazard.  Contract professional electrician to evaluate and correct to avoid associated electrical safety hazards and maintain proper system performance.  No associated damages visible during time of inspection.
16.1 Item 5(Picture) - Double tapped breaker inside 11264 panel
16.1 Item 6(Picture) - Double tapped breaker inside 11256 panel
16.3  GROUNDING  
Specialist Item.
11266/11260/11256 - No main grounding conductor installed.  Installation necessary to maintain electrical grounding protection to home.  Contract licensed electrician to properly correct and restore electrical safety to system and occupants.


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Steve Rodriguez

Top Table of Contents Bottom

Maintenance Item Summary


Client
Smart Investor

Property Address
6 Unit Property
Kansas City MO 64137

The following items or discoveries indicate that these systems or components do not function as intended but is considered maintenance in nature. Maintenance items that are not corrected could lead to further damage and cost more to repair.Please refer to the Major Item Summary for more significant repairs. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

1.  LANDSCAPING
1.0  LANDSCAPING AND DRAINAGE  
Maintenance Item.
Landscaping is flat and slopes toward building at various areas actions building.  This is a typical condition found in many properties.  Recommend sloping grading away from building 1" per foot out to 6 feet to provide proper drainage and reduce possible foundation shifting (85-90% of all foundation moisture problems can be avoided with proper grading and downspout extensions).  None visible during time of inspection.
1.0 Item 1(Picture) - Landscaping slopes toward building on East side
1.0 Item 2(Picture) - Landscaping slopes toward building at NW corner
1.0 Item 3(Picture) - Landscaping slopes toward building at SW corner
1.1  DRIVEWAY AND PARKING LOT  
Maintenance Item.
Driveway has cracked and deteriorated to a point where it creates a trip hazard.  .  Recommend hiring professional driveway contractor to evaluate and repair to avoid continued deterioration and future personal injury. 
1.1 Item 1(Picture) - Worn and deteriorated asphalt in parking lot
1.2  WALKWAY  
Maintenance Item.
11256 - Open space beneath walkway due to grading settlement.  This does not pose an immediate structural issue, but recommend filling space with concrete to avoid future movement and associated structural damages.  None visible during time of inspection.
1.2 Item 1(Picture) - Space beneath 1256 walkway
1.4  PATIO  
Maintenance Item.
(1) 11258/11260 - Patio slopes to the South.  This is not structurally significant to home, but does make patio difficult to use.  Recommend careful mud jacking to correct and avoid continued movement.   No associated structural damages visible during time of inspection.
1.4 Item 1(Picture) - 11258 patio slopes away from building
1.4 Item 2(Picture) - 11260 patio slopes away from building
(2) 11266 - Patio slopes toward home.  This is caused by grading movement and is potentially damaging to foundation.  Recommend hiring professional patio contractor to evaluate and repair to avoid possible moisture seepage within basement.  None visible during time of inspection.
1.4 Item 3(Picture) - 11266 patio slopes toward foundation

2.  EXTERIOR COMPONENTS
2.1  WALL SIDING, FLASHING, AND TRIM  
Maintenance Item.
(1) Exposed nails, peeling paint, and rot at siding and trim around building .  Recommend properly repairing and repainting all damaged areas to avoid continued damage and possible moisture penetration within underlying framing areas.  Unable to determine if any underlying damages exist during time of inspection.
2.1 Item 1(Picture) - Rot on East side of building
2.1 Item 2(Picture) - Other area of rot on East side of building
2.1 Item 3(Picture) - Rot above 11262 entryway
2.1 Item 4(Picture) - Rot at base of siding on East side
2.1 Item 5(Picture) - Rot at base of siding at 11260
2.1 Item 6(Picture) - Rot on West side of building
2.1 Item 7(Picture) - Rot behind trim on West side of building
2.1 Item 8(Picture) - Rot at SW corner of building
(2) Vegetation too close to siding around building.  This will lead to premature siding wear, moisture problems within wall, and creates an easy path for wood destroying insects to enter home.  Recommend trimming back all vegetation at least 12" to avoid associated damages.  None visible during time of inspection.
2.1 Item 9(Picture) - Vegetation on East side
2.1 Item 10(Picture) - Vegetation at NE corner of building
(3) Ivy growth around building This crawls under siding and gets into home. .  Recommend removing to reduce associated underlying damages.  None visible during time of inspection.
2.1 Item 11(Picture) - Ivy growth on West side of building
2.2  WINDOWS  
Maintenance Item.
Peeling paint and rot at window frames and sills around building.  Recommend properly repairing and repainting to avoid continued damage to underlying framing areas. No underlying moisture damages visible during time of inspection.
2.2 Item 1(Picture) - Rot and peeling paint on East side of building
2.2 Item 2(Picture) - Rot and peeling paint at West side windows

3.  CENTRAL COOLING
3.0  COMPRESSOR UNIT  
Specialist Item.
(2) 11256 - Outdoor unit is 18 years old, rusty, and nearing the end of its useful life.  It operates as intended during time of inspection; however, recommend servicing to maximize performance.  Additionally, recommend providing annual system maintenance to maximize efficiency and extend useful life.  Budget for replacement.
3.0 Item 5(Picture) - 11256 condenser is 18 years old and rusty
(3) 11258 - Dirty fins at exterior condenser unit.  Recommend cleaning (spray off with hose) to maximize life and efficiency.  Unit operates properly during time of inspection.
3.0 Item 6(Picture) - Dirty fins at 11258 condenser unit
(5) 11264 - Outdoor unit is approx. 30 years old, rusty, and nearing the end of its useful life.  It operates as intended during time of inspection; however, recommend servicing to maximize performance.  Additionally, recommend providing annual system maintenance to maximize efficiency and extend useful life.  Budget to replace.
(7) 11266 - Soil has been built up around compressor unit.  Recommend removing to avoid deterioration and associated damages.  None visible during time of inspection.
3.0 Item 10(Picture) - Soil up around 11266 A/C unit
(8) 11266 - Outdoor unit is damaged.  It appears unit has been hit with lawn mower.  Recommend repairing to maintain proper performance.  Unit operates properly during time of inspection.
3.0 Item 11(Picture) - 11266 A/C is damaged
3.1  REFRIGERANT LINES  
Specialist Item.
(2) 11260/11262 - Worn and deteriorated insulation at A/C refrigerant line.  This will lower overall efficiency of system.  Recommend repairing to ensure maximum efficiency.
3.1 Item 2(Picture) - Worn insulation at 11260 refrigerant lines
3.1 Item 3(Picture) - Missing insulation in at 11262

4.  ROOF SYSTEM
4.0  GUTTERS, DOWNSPOUTS, AND DRAINAGE  
Maintenance Item.
Downspout drains water too close to foundation on East side of building. Recommend extending at least 6' away from foundation wall to avoid possibility of moisture penetration and associated damages.  None visible during time of inspection.
4.0 Item 1(Picture) - Extend downspout on East side
4.1  SOFFITS AND FASCIAS  
Maintenance Item.
Peeling paint and rot soffit/fascia boards around building.  Recommend properly repairing and repainting all damaged areas to extend their useful life.  No significant damages visible during time of inspection.
4.1 Item 1(Picture) - Peeling paint on East side
4.1 Item 2(Picture) - Peeling paint above 11260
4.1 Item 3(Picture) - Rot in soffit on West side
4.1 Item 4(Picture) - Hole in soffit at SW corner of roof
4.1 Item 5(Picture) - Rot and peeling paint on West side
4.1 Item 6(Picture) - Rot at 11264 Soffit on West side
4.1 Item 7(Picture) - Peeling paint and rot on South side

5.  ATTIC AND ROOF STRUCTURE
5.0  ROOF STRUCTURE  
Maintenance Item.
11266 - Split roof rafter visible on South side of attic.  This indicates possible point of weakness.  Recommend properly repairing to maintain designed weight bearing capacity to roof structure.  No underlying structural damages visible during time of inspection.
5.0 Item 1(Picture) - Split roof rafter in 11266 attic
5.1  INSULATION  
Maintenance Item.
11262 - 3 inches of blown fiberglass insulation present.  U.S. Department of Energy recommends R-38 rating in attic spaces, which equates to 13 inches.  Consider providing additional depth to maintain intended energy efficiency to home and reduce associated fuel costs.
5.1 Item 1(Picture) - 3 inches of blown fiberglass insulation in all attics

6.  ROOMS
6.3  WINDOWS  
Maintenance Item.
(1) 11262 - Window missing latch on North bedroom. Recommend installing to provide intended security protection to home. 
(2) 11262 - Window assist/lift components are not working properly in South bedroom (window will not stay up). Recommend repairing to restore proper window performance. 
6.6  LIGHTING  
Maintenance Item.
11266 - Light out.  Replace bulb.  If this does not correct, recommend contracting electrician to investigate and correct to restore safe and proper operation.

7.  BATHROOM
7.1  FLOOR  
Maintenance Item.
11260 - Missing caulking at base of tub enclosure.  Recommend properly sealing to reduce possible moisture penetration and associated damages. Floor is soft and slopes toward tub during time of inspection.
7.1 Item 1(Picture) - Missing caulking at 11260 floor
7.2  WALLS  
Maintenance Item.
11266 - Superficial mold growth visible at upstairs bathroom wall, but no moisture detected during time of inspection.  This appears to be caused from active moisture leaks within bathroom.  Recommend cleaning wall to avoid associated moisture damage.  None visible during time of inspection.
7.2 Item 1(Picture) - Superficial mold in 11266 bathroom wall
7.3  CEILING  
Maintenance Item.
11264 - Old moisture stains visible at half bath ceiling, but no moisture detected during time of inspection.  This appears to be caused from overflow or leak at hall bath, above.  Recommend properly sealing and painting to avoid future moisture damage.  No underlying damages visible during time of inspection.
7.3 Item 1(Picture) - Old moisture stains in 11264 half bath ceiling
7.6  LIGHTING  
Specialist Item.
(2) 11264 - Light out in half bath.  Replace bulb.  If this does not correct, recommend contracting electrician to investigate and correct to restore safe and proper operation.
7.9  SINK, FAUCET, PLUMBING, AND TRAP DRAIN  
Not Present., Maintenance Item.
(1) 11262 - Active leakage at sink basin in upstairs bath.  Recommend properly repairing to avoid further leakage and associated moisture damages.  No significant damages visible during time of inspection.
7.9 Item 1(Picture) - Leak at 11262 sink basin
(2) 11266 - Faucet leaks in upstairs bath. Recommend repairing to restore operation. 
(3) 11264 - Faucet is loose in half bath.  .  Recommend properly securing to avoid any possible inadvertent piping damages during use.  None visible during time of inspection.
(4) 11260 - Active leakage beneath both sinks.  Recommend properly repairing to avoid further leakage and associated moisture damages.  Moisture damages visible beneath left sink during time of inspection.
7.9 Item 2(Picture) - Active leak beneath both sink in 11260 upstairs bath
(5) Slow drain at left sink.  Recommend cleaning to restore proper drainage.  If this does not correct, contract plumber to investigate and repair to avoid possible overflow.  No associated damages visible during time of inspection.
7.11  TOILET  
Maintenance Item.
(1) 11262 - Upstairs toilet is loose and leaking.  Recommend properly repairing to avoid future damages to underlying framing members.  Unable to determine extent of underlying damages during time of inspection.
7.11 Item 1(Picture) - Leakage at 11262 upstairs toilet
(2) 11262/11266/12258 - Half bath toilet is loose.  This condition will eventually worsen and leak if not repaired.  Recommend properly securing to avoid future leakage and associated damages.  None visible during time of inspection.
(3) 11266/11264/11260/11258/11256 - Upstairs toilet is loose.  This condition will eventually worsen and leak if not repaired.  Recommend properly securing to avoid future leakage and associated damages.  None visible during time of inspection.
(4) 11264 - Toilet flush handle is broken in half bath.  Recommend repairing to restore proper operation. 
(5) 11260 - Half bath toilet is loose and leaking.  Recommend properly repairing to avoid further leakage and associated moisture damages.  Unable to determine extent of underlying damages during time of inspection.
7.12  TUB AND ENCLOSURE  
Maintenance Item.
(1) 11262 - Loose shower head piping and faucet in upstairs bath.  Recommend properly securing to avoid possible leakage due to movement.  None visible during time of inspection.
(2) 11262 - Tub faucet is leaking.  Recommend repairing to restore proper operation. 
(3) 11264 - Deteriorated caulking at base of tub enclosure.  Recommend properly recaulking to reduce possible moisture penetration and associated damages. None visible during time of inspection.
7.12 Item 1(Picture) - Deteriorated caulking at base of 11264 tub enclosure
(4) 11260/11256 - Loose shower head piping.  Recommend properly securing to avoid possible leakage due to movement.  None visible during time of inspection.
(5) 11258 - Faucet diverter is stuck closed (only shower works).  Recommend repairing to restore proper operation. 

8.  COMMON AREAS
8.7  FRONT DOOR  
Maintenance Item.
11266 - Deteriorated weatherstripping around front door.  Recommend repairing to reduce possible moisture penetration and increase energy efficiency to space.
8.7 Item 1(Picture) - Deteriorated caulking around 11266 front door

9.  KITCHEN AND COMPONENTS
9.8  SINK, FAUCET, PLUMBING, AND TRAP DRAIN  
Maintenance Item.
11264 - Active leakage beneath sink.  Recommend properly repairing to avoid further leakage and associated moisture damages.  No significant damages visible during time of inspection.
9.8 Item 1(Picture) - Active leakage beneath 11264 kitchen sink
9.13  RANGE HOOD  
Maintenance Item.
11264/11260 - Light is out.  Replace bulb.  If this does not correct, recommend contracting electrician to investigate and repair as necessary to restore proper operation.

10.  LIVING ROOM
10.4  PATIO DOOR  
Maintenance Item.
11266 - Active leakage around patio door.  Recommend hiring professional contractor to evaluate and repair to maintain proper performance. Unable to determine extent of underlying damages during time of inspection.

11.  DINING ROOM
11.4  LIGHTING  
Maintenance Item.
11266 - Light out. Replace bulb.  If this does not correct, recommend contracting electrician to investigate and correct to restore safe and proper operation.

12.  BASEMENT/CRAWLSPACE/SUB-BASEMENT
12.2  FOUNDATION / WALLS  
Specialist Item.
(2) 11256 - Superficial mold visible on wall.  This is likely due to basement bring dark and dryer venting into space.  Recommend cleaning wall and installing dehumidifier within basement to avoid associated health hazards.  No moisture damages visible during time of inspection.
12.2 Item 2(Picture) - Mold on walls in 11256 basement
12.2 Item 3(Picture) - More mold in 11256 basement
12.2 Item 4(Picture) - And more superficial mold in 11256 basement

14.  CENTRAL HEATING
14.1  HEATING EQUIPMENT  
Maintenance Item.
(1) 11262/11260/11256 - Furnace is 20 years old (expected life is 20-25 years) and displays heavy rust and corrosion in burner/heat exchanger areas.  Unable to determine extent of underlying damages, but unit performs as intended during time of inspection.  Recommend having unit serviced regularly to maximize life and system efficiency.  Budget for future replacement.
14.1 Item 1(Picture) - Rust and corrosion in 11262 furnace
14.1 Item 2(Picture) - Rust and corrosion inside 11260 furnace
14.1 Item 3(Picture) - Rust and corrosion inside 11256 furnace
14.4  CHIMNEYS, FLUES AND VENTS  
Maintenance Item.
(1) 11262 - HVAC supply vent is disconnected within basement.  Recommend properly sealing with metallic tape to maximize system efficiency.
14.4 Item 1(Picture) - Vent disconnected inside 11262 basement
(2) 11262 - Duct tape used to seal seams at HVAC vents.  This is improper and tape will ultimately become dry and brittle.  Recommend properly sealing all open seams with metal tape then properly insulating ducting to maximize flow and efficiency to home.
14.4 Item 2(Picture) - Duct tape at vents in 11262 basement
14.8  FURNACE ENCLOSURE  
Maintenance Item.
11262/11264/11260 - Air leaks at seams around furnace enclosure.  This is inefficient.  Recommend sealing all leaks with metallic tape to maximize system efficiency and improve performance.
14.8 Item 1(Picture) - Air leaks around 11262 furnace enclosure
14.8 Item 2(Picture) - Air leaks around 11264 furnace enclosure
14.8 Item 3(Picture) - Air leak at 11260 refrigerant lines

15.  PLUMBING SYSTEM
15.1  MAIN WATER SHUT-OFF  
Maintenance Item.
11262/11260 - Active leakage in water main valve.  Recommend contracting professional plumber to evaluate and repair to avoid continued leakage and possible moisture damage.  None visible during time of inspection.
15.1 Item 1(Picture) - Active leakage at 11262 water main
15.1 Item 2(Picture) - Active leakage at 11260 water main
15.6  WATER HEATER  
Maintenance Item.
(1) 11262/11266/11264/11260/11258/11256 - Active leakage at drip tube.  This can be caused by high tank pressure or sediment beneath valve seat.  Recommend contracting professional plumber to evaluate and repair to restore proper performance.  No associated damages visible during time of inspection.
15.6 Item 1(Picture) - Active leak at 11262 water heater relief valve
15.6 Item 2(Picture) - Active leak at 11266 relief valve
15.6 Item 3(Picture) - Active leak at 11264 relief valve
15.6 Item 4(Picture) - Active leak at 11260 relief valve
15.6 Item 5(Picture) - Active leak at 11258 relief valve
(2) 11262/11258 - Rust and corrosion in and around water heater.  Units are 13 & 8 years old and operate as intended during time of inspection.  These conditions and its age (typical life of water heater is 10-12 years) indicate unit is at the end of its useful life.  Budget for replacement.
15.6 Item 6(Picture) - Rust at base of 11262 water heater
15.6 Item 7(Picture) - Corrosion on top of 11258 water heater
(4) 11266 - Rust and corrosion in and around water heater.  Unit is 17 years old and operates as intended during time of inspection.  These conditions and its age (typical life of water heater is 10-12 years) indicate unit is at the end of its useful life.  Budget to replace.
15.6 Item 9(Picture) - Rust around 11266 water heater
(5) 11260 - Active leakage at drain bibb.  Recommend hiring professional plumber to evaluate and repair to reduce continued leakage and associated moisture damages.  Moisture damages visible during time of inspection.
15.6 Item 10(Picture) - Active leakage at 11260 drain bibb

16.  ELECTRICAL SYSTEMS
16.1  DISTRIBUTION PANEL  
Maintenance Item.
(1) 11262/11266/11264/11260/11258/11256 - Zinsco main distribution panel installed.  These panels were originally made in Puerto Rico and installed in the 60's and 70's throughout the USA.  There are many still in use in both single-family and multi-family units.  Zinsco sold their manufacturing plants to Sylvania who then marketed them under the GTE Sylvania brand until finally closing down.  Today, the Zinsco name is owned by Thomas and Betts. 

Major Problems: 

1) It has been found that circuit breakers do not trip under normal overload conditions (It has been known to sometimes take up to 60-amps to trip a 15-amp Zinsco breaker. 

2) The parallel flat buss bars are made of aluminum material and corrode quite easily, increasing the electrical resistance at point of contact and causing panels to overheat. 

3) The plating that coats the buss bars sometimes fails on many Zinsco panels, causing poor circuit breaker connections. 

4) Another problem is that the breakers do not have designated positions, i.e., they can slide up and down the buss bar, are often crooked, and it is not uncommon to see gaps between the breakers with the deadfront cover in place. 

Recommend monitoring panel for signs of overheating.  No signs of past problems visible during time of inspection.

16.1 Item 1(Picture) - This is a Zinsco panel
(3) 11262/11266 - Knockout missing.  These are necessary to maintain designed electrical safety and avoid rodent intrusion.  Recommend contracting electrician to install and avoid associated electrical safety hazards.
16.1 Item 3(Picture) - Missing knockout at 11262 panel
16.1 Item 4(Picture) - Missing knockout at 11266 panel
(5) 11258 - Twistout missing.  These are necessary to maintain designed electrical safety and avoid rodent intrusion.  Recommend contracting electrician to install and avoid associated electrical safety hazards.
16.1 Item 7(Picture) - Missing twistout in 11258 panel


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Steve Rodriguez

Top Table of Contents Bottom

This Page Begins Your Full Home Inspection Report

Date: 5/11/2021 Time: 10:00 AM Report ID: 20170605-6-unit-property
Property:
6 Unit Property
Kansas City MO 64137
Customer:
Smart Investor
Real Estate Professional:
Great Agent

Comment Key or Definitions

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor and all costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.

Inspected.  Good Or Working Condition. (IN) = The item, component or unit was visually observed and appeared sound or functioning as intended.

Not Inspected. (NI) = The item, component or unit was not inspected.  However, in the interest of the client and whenever possible, stated observations are made based upon visually verifiable conditions or accessible areas.  Please be aware that the nature of these observations prevent reporting on hidden areas with certainty.

Not Present. (NP) = This item, component or unit is not in this home or building.

Maintenance Item. (MN) = The item, component or unit appears deficient or needs repair or maintenance by homeowner or qualified contractor.  Items, components or units that can be repaired to satisfactory condition may not need replacement.

Major Item. (MJ) = The item, component or unit is deficient or needs further inspection, service or repair by a qualified/licensed contractor or qualified specialist.  Items, components or units that can be repaired to satisfactory condition may not need replacement.

Safety Item. (SI) = The item, component or unit is deficient and/or  presents a safety hazard to the occupants and/or the dwelling.  Items, components or units that can be repaired to satisfactory condition may not need replacement.

Type Of Building:
MULTI-FAMILY

Age Of Building:
44

Occupancy:
OCCUPIED

Beds and Baths:
2 BED 1.5 BATH

Building Faces:
EAST

Fire Hydrant:
WITHIN 25 feet

Termite Inspection:
YES

Temperature:
OVER 60

Weather:
CLEAR AND WARM

Rain in last 3 days:
YES

  
Top Table of Contents Bottom
1.  LANDSCAPING
Styles & Materials
Driveway:
ASPHALT
Walkway:
CONCRETE
Porch:
CONCRETE
Patio:
CONCRETE
   
Items
1.0 LANDSCAPING AND DRAINAGE
Comments: Maintenance Item.
Landscaping is flat and slopes toward building at various areas actions building.  This is a typical condition found in many properties.  Recommend sloping grading away from building 1" per foot out to 6 feet to provide proper drainage and reduce possible foundation shifting (85-90% of all foundation moisture problems can be avoided with proper grading and downspout extensions).  None visible during time of inspection.
1.0 Item 1(Picture) - Landscaping slopes toward building on East side
1.0 Item 2(Picture) - Landscaping slopes toward building at NW corner
1.0 Item 3(Picture) - Landscaping slopes toward building at SW corner
1.1 DRIVEWAY AND PARKING LOT
Comments: Maintenance Item.
Driveway has cracked and deteriorated to a point where it creates a trip hazard.  .  Recommend hiring professional driveway contractor to evaluate and repair to avoid continued deterioration and future personal injury. 
1.1 Item 1(Picture) - Worn and deteriorated asphalt in parking lot
1.2 WALKWAY
Comments: Maintenance Item.
11256 - Open space beneath walkway due to grading settlement.  This does not pose an immediate structural issue, but recommend filling space with concrete to avoid future movement and associated structural damages.  None visible during time of inspection.
1.2 Item 1(Picture) - Space beneath 1256 walkway
1.3 PORCH
Comments: Inspected. Appears Good Or In Working Condition.
1.4 PATIO
Comments: Maintenance Item.
(1) 11258/11260 - Patio slopes to the South.  This is not structurally significant to home, but does make patio difficult to use.  Recommend careful mud jacking to correct and avoid continued movement.   No associated structural damages visible during time of inspection.
1.4 Item 1(Picture) - 11258 patio slopes away from building
1.4 Item 2(Picture) - 11260 patio slopes away from building
(2) 11266 - Patio slopes toward home.  This is caused by grading movement and is potentially damaging to foundation.  Recommend hiring professional patio contractor to evaluate and repair to avoid possible moisture seepage within basement.  None visible during time of inspection.
1.4 Item 3(Picture) - 11266 patio slopes toward foundation
Top Table of Contents Bottom
2.  EXTERIOR COMPONENTS
The home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility.
Styles & Materials
Foundation Walls:
POURED CONCRETE
Siding Materials:
COMPOSITE BOARD
 
Items
2.0 EXTERIOR FOUNDATION WALLS
Comments: Inspected. Appears Good Or In Working Condition.
2.1 WALL SIDING, FLASHING, AND TRIM
Comments: Maintenance Item.
(1) Exposed nails, peeling paint, and rot at siding and trim around building .  Recommend properly repairing and repainting all damaged areas to avoid continued damage and possible moisture penetration within underlying framing areas.  Unable to determine if any underlying damages exist during time of inspection.
2.1 Item 1(Picture) - Rot on East side of building
2.1 Item 2(Picture) - Other area of rot on East side of building
2.1 Item 3(Picture) - Rot above 11262 entryway
2.1 Item 4(Picture) - Rot at base of siding on East side
2.1 Item 5(Picture) - Rot at base of siding at 11260
2.1 Item 6(Picture) - Rot on West side of building
2.1 Item 7(Picture) - Rot behind trim on West side of building
2.1 Item 8(Picture) - Rot at SW corner of building
(2) Vegetation too close to siding around building.  This will lead to premature siding wear, moisture problems within wall, and creates an easy path for wood destroying insects to enter home.  Recommend trimming back all vegetation at least 12" to avoid associated damages.  None visible during time of inspection.
2.1 Item 9(Picture) - Vegetation on East side
2.1 Item 10(Picture) - Vegetation at NE corner of building
(3) Ivy growth around building This crawls under siding and gets into home. .  Recommend removing to reduce associated underlying damages.  None visible during time of inspection.
2.1 Item 11(Picture) - Ivy growth on West side of building
2.2 WINDOWS
Comments: Maintenance Item.
Peeling paint and rot at window frames and sills around building.  Recommend properly repairing and repainting to avoid continued damage to underlying framing areas. No underlying moisture damages visible during time of inspection.
2.2 Item 1(Picture) - Rot and peeling paint on East side of building
2.2 Item 2(Picture) - Rot and peeling paint at West side windows
2.3 WINDOW WELLS
Comments: Inspected. Appears Good Or In Working Condition.
2.4 EXTERIOR DOORS
Comments: Safety Item.
11260/11258/11266 - Patio has big step into home.  Maximum height should be 8" (step is currently 12" high).  Recommend adding intermediate step to avoid associated tripping hazard.
2.4 Item 1(Picture) - Large step into 11260
2.4 Item 2(Picture) - Large step into 11258
2.4 Item 3(Picture) - Large step into 11266
2.5 EXTERIOR LIGHTING
Comments: Inspected. Appears Good Or In Working Condition.
2.6 OTHER DISCOVERIES
Comments: Not Present.
The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
3.  CENTRAL COOLING
11256
11258
11260
11262
11264
11266
Styles & Materials
Cooling Unit Type:
A/C
Temperature Differential:
18-22 DEG.
Cooling Unit Manufacturer:
BRYANT
CARRIER
NORDYNE
YORK
Cooling Unit Age:
APPROX.
4
11
12
18
30
   
Items
3.0 COMPRESSOR UNIT
Comments: Specialist Item.
(1) 11256/11262/11264/11266 - Outdoor unit is not level.  Excessive movement can crack HP/LP tubing at connections.  Unit works as intended during time of inspection, but recommend bringing unit to within 1 inch of level to maintain proper performance.
3.0 Item 1(Picture) - 11256 condenser unit not level
3.0 Item 2(Picture) - 11262 condenser not level
3.0 Item 3(Picture) - 11264 condenser is not level
3.0 Item 4(Picture) - 11266 A/C condenser is not level
(2) 11256 - Outdoor unit is 18 years old, rusty, and nearing the end of its useful life.  It operates as intended during time of inspection; however, recommend servicing to maximize performance.  Additionally, recommend providing annual system maintenance to maximize efficiency and extend useful life.  Budget for replacement.
3.0 Item 5(Picture) - 11256 condenser is 18 years old and rusty
(3) 11258 - Dirty fins at exterior condenser unit.  Recommend cleaning (spray off with hose) to maximize life and efficiency.  Unit operates properly during time of inspection.
3.0 Item 6(Picture) - Dirty fins at 11258 condenser unit
(4) 11262/11264 - Broken electrical conduit at condenser unit.  This makes wiring vulnerable to inadvertent damage.  Recommend contracting professional HVAC technician to repair to maintain associate safe and proper performance.  Unit operates properly during time of inspection.
3.0 Item 7(Picture) - Broken conduit at 11262 A/C
3.0 Item 8(Picture) - Broken conduit at 11264 A/C unit
(5) 11264 - Outdoor unit is approx. 30 years old, rusty, and nearing the end of its useful life.  It operates as intended during time of inspection; however, recommend servicing to maximize performance.  Additionally, recommend providing annual system maintenance to maximize efficiency and extend useful life.  Budget to replace.
(6) 11264 - Damaged fins at exterior condenser unit.  Recommend contracting licensed HVAC technician to repair to maintain proper condenser performance.  Unit operates properly during time of inspection.
3.0 Item 9(Picture) - Dirty fins at 11264 condenser unit
(7) 11266 - Soil has been built up around compressor unit.  Recommend removing to avoid deterioration and associated damages.  None visible during time of inspection.
3.0 Item 10(Picture) - Soil up around 11266 A/C unit
(8) 11266 - Outdoor unit is damaged.  It appears unit has been hit with lawn mower.  Recommend repairing to maintain proper performance.  Unit operates properly during time of inspection.
3.0 Item 11(Picture) - 11266 A/C is damaged
3.1 REFRIGERANT LINES
Comments: Specialist Item.
(1) 11258 - A/C refrigerant lines have iced up at condenser.  This is often caused by low refrigerant, a clogged filter, or a clogged evaporator coil.  Recommend contracting professional HVAC contractor to evaluate and repair to maintain proper system performance.  A/C is blowing warm during time of inspection.
3.1 Item 1(Picture) - Refrigerant lines have iced up
(2) 11260/11262 - Worn and deteriorated insulation at A/C refrigerant line.  This will lower overall efficiency of system.  Recommend repairing to ensure maximum efficiency.
3.1 Item 2(Picture) - Worn insulation at 11260 refrigerant lines
3.1 Item 3(Picture) - Missing insulation in at 11262
3.2 EVAPORATOR UNIT
Comments: Specialist Item.
(1) 11258 - Evaporator is actively leaking behind furnace enclosure.  This is often caused by cracked pan or clogged drain.  If left unattended, this condition may ultimately crack the heat exchanger and cause premature furnace replacement.  Recommend contracting licensed HVAC technician to repair to maximize remaining life and system performance.  No significant damages visible during time of inspection.
3.2 Item 1(Picture) - 11258 evaporator is leaking behind furnace
(2) 11256 - Evaporator is actively leaking on top of furnace enclosure.  This is often caused by cracked pan or clogged drain.  If left unattended, this condition may ultimately crack the heat exchanger and cause premature furnace replacement.  Recommend contracting licensed HVAC technician to repair to maximize remaining life and system performance.  No significant damages visible during time of inspection.
3.2 Item 2(Picture) - Evaporator leakage on top of 11256
3.3 AIR DISTRIBUTION SYSTEM
Comments: Inspected. Appears Good Or In Working Condition.
3.4 NORMAL OPERATING CONTROLS
Comments: Not Inspected.
Top Table of Contents Bottom
4.  ROOF SYSTEM
The home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing. The home inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors.
Styles & Materials
Viewed Roof Covering From:
GROUND
ROOF EDGE
Limitations:
HEIGHT
Roof Type:
GABLE
Age Of Shingles:
4
Roof Pitch:
4-12
Number Of Layers:
1
Fascia / Soffit:
WOOD
Roof Covering:
ASPHALT/FIBERGLASS
Life Expectancy:
NEARING MIDDLE
Items
4.0 GUTTERS, DOWNSPOUTS, AND DRAINAGE
Comments: Maintenance Item.
Downspout drains water too close to foundation on East side of building. Recommend extending at least 6' away from foundation wall to avoid possibility of moisture penetration and associated damages.  None visible during time of inspection.
4.0 Item 1(Picture) - Extend downspout on East side
4.1 SOFFITS AND FASCIAS
Comments: Maintenance Item.
Peeling paint and rot soffit/fascia boards around building.  Recommend properly repairing and repainting all damaged areas to extend their useful life.  No significant damages visible during time of inspection.
4.1 Item 1(Picture) - Peeling paint on East side
4.1 Item 2(Picture) - Peeling paint above 11260
4.1 Item 3(Picture) - Rot in soffit on West side
4.1 Item 4(Picture) - Hole in soffit at SW corner of roof
4.1 Item 5(Picture) - Rot and peeling paint on West side
4.1 Item 6(Picture) - Rot at 11264 Soffit on West side
4.1 Item 7(Picture) - Peeling paint and rot on South side
4.2 ROOF COVERINGS
Comments: Inspected. Appears Good Or In Working Condition.
4.3 ROOF VENTILATION
Comments: Inspected. Appears Good Or In Working Condition.
4.4 FLASHINGS
Comments: Inspected. Appears Good Or In Working Condition.
4.5 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
Comments: Inspected. Appears Good Or In Working Condition.
The roof of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
5.  ATTIC AND ROOF STRUCTURE
11262
Styles & Materials
Method Used To Observe Attic:
FROM ENTRY
Limitations:
INSULATION
Roof Structure:
PLYWOOD
WOOD RAFTER
Attic Insulation:
BLOWN FIBERGLASS
Ventilation:
GABLE END
ROOF
 
Items
5.0 ROOF STRUCTURE
Comments: Maintenance Item.
11266 - Split roof rafter visible on South side of attic.  This indicates possible point of weakness.  Recommend properly repairing to maintain designed weight bearing capacity to roof structure.  No underlying structural damages visible during time of inspection.
5.0 Item 1(Picture) - Split roof rafter in 11266 attic
5.1 INSULATION
Comments: Maintenance Item.
11262 - 3 inches of blown fiberglass insulation present.  U.S. Department of Energy recommends R-38 rating in attic spaces, which equates to 13 inches.  Consider providing additional depth to maintain intended energy efficiency to home and reduce associated fuel costs.
5.1 Item 1(Picture) - 3 inches of blown fiberglass insulation in all attics
5.2 ATTIC ACCESS
Comments: Inspected. Appears Good Or In Working Condition.
5.3 VENTILATION, FANS, AND EXHAUST DUCTING
Comments: Inspected. Appears Good Or In Working Condition.
5.4 SKYLIGHTS, CHIMNEYS, AND ROOF PENETRATIONS ( ATTIC VIEW)
Comments: Inspected. Appears Good Or In Working Condition.
5.5 CIRCUIT WIRING
Comments: Inspected. Appears Good Or In Working Condition.
Much of circuit wiring concealed beneath insulation, limiting degree of visual inspection.  All reported conditions based upon visually verifiable areas.
Top Table of Contents Bottom
6.  ROOMS
The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.
Styles & Materials
Floor:
CARPET
Wall:
DRYWALL
Ceiling:
DRYWALL
Windows:
ALUMINUM
SINGLE HUNG
Door:
WOOD
HINGED
Closet / Door:
METAL
WOOD
FOLDING
SLIDING
ATTIC ACCESS
Items
6.0 FLOOR
Comments: Inspected. Appears Good Or In Working Condition.
6.1 WALLS
Comments: Inspected. Appears Good Or In Working Condition.
6.2 CEILING
Comments: Inspected. Appears Good Or In Working Condition.
6.3 WINDOWS
Comments: Maintenance Item.
(1) 11262 - Window missing latch on North bedroom. Recommend installing to provide intended security protection to home. 
(2) 11262 - Window assist/lift components are not working properly in South bedroom (window will not stay up). Recommend repairing to restore proper window performance. 
6.4 DOOR
Comments: Inspected. Appears Good Or In Working Condition.
6.5 CLOSET/DOOR
Comments: Inspected. Appears Good Or In Working Condition.
6.6 LIGHTING
Comments: Maintenance Item.
11266 - Light out.  Replace bulb.  If this does not correct, recommend contracting electrician to investigate and correct to restore safe and proper operation.
6.7 RECEPTACLES AND SWITCHES
Comments: Inspected. Appears Good Or In Working Condition.
6.8 HEAT SOURCE
Comments: Inspected. Appears Good Or In Working Condition.
6.9 SMOKE DETECTOR
Comments: Safety Item.
11262/11266/11264/11260 - Smoke detectors missing in ALL bedrooms.   Installation necessary to provide necessary early fire/smoke detection to spaces.
The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
7.  BATHROOM
Styles & Materials
Exhaust Fan Type:
FAN WITH LIGHT
Floor:
VINYL
Wall:
DRYWALL
Ceiling:
DRYWALL
Windows:
ALUMINUM
SINGLE HUNG
Vanity / Cabinetry / Countertops:
LAMINATE
WOOD CABINET
Tub Enclosure:
CERAMIC TILE
PLASTIC ENCLOSURE
GFCI Protection:
IN SAME SPACE
 
Items
7.0 FUNCTIONAL FLOW
Comments: Inspected. Appears Good Or In Working Condition.
7.1 FLOOR
Comments: Maintenance Item.
11260 - Missing caulking at base of tub enclosure.  Recommend properly sealing to reduce possible moisture penetration and associated damages. Floor is soft and slopes toward tub during time of inspection.
7.1 Item 1(Picture) - Missing caulking at 11260 floor
7.2 WALLS
Comments: Maintenance Item.
11266 - Superficial mold growth visible at upstairs bathroom wall, but no moisture detected during time of inspection.  This appears to be caused from active moisture leaks within bathroom.  Recommend cleaning wall to avoid associated moisture damage.  None visible during time of inspection.
7.2 Item 1(Picture) - Superficial mold in 11266 bathroom wall
7.3 CEILING
Comments: Maintenance Item.
11264 - Old moisture stains visible at half bath ceiling, but no moisture detected during time of inspection.  This appears to be caused from overflow or leak at hall bath, above.  Recommend properly sealing and painting to avoid future moisture damage.  No underlying damages visible during time of inspection.
7.3 Item 1(Picture) - Old moisture stains in 11264 half bath ceiling
7.4 WINDOW
Comments: Inspected. Appears Good Or In Working Condition.
7.5 DOOR
Comments: Inspected. Appears Good Or In Working Condition.
7.6 LIGHTING
Comments: Specialist Item.
(1) 11262/11260 - Lighting is on GFCI circuit in main floor half bath.  This is improper since lights will not work if GFCI circuit is tripped.  Recommend contracting professional electrician to place lights on dedicated circuit to maintain constant, reliable function.
(2) 11264 - Light out in half bath.  Replace bulb.  If this does not correct, recommend contracting electrician to investigate and correct to restore safe and proper operation.
7.7 RECEPTACLES AND SWITCHES
Comments: Inspected. Appears Good Or In Working Condition.
7.8 EXHAUST FAN
Comments: Not Present.
7.9 SINK, FAUCET, PLUMBING, AND TRAP DRAIN
Comments: Not Present., Maintenance Item.
(1) 11262 - Active leakage at sink basin in upstairs bath.  Recommend properly repairing to avoid further leakage and associated moisture damages.  No significant damages visible during time of inspection.
7.9 Item 1(Picture) - Leak at 11262 sink basin
(2) 11266 - Faucet leaks in upstairs bath. Recommend repairing to restore operation. 
(3) 11264 - Faucet is loose in half bath.  .  Recommend properly securing to avoid any possible inadvertent piping damages during use.  None visible during time of inspection.
(4) 11260 - Active leakage beneath both sinks.  Recommend properly repairing to avoid further leakage and associated moisture damages.  Moisture damages visible beneath left sink during time of inspection.
7.9 Item 2(Picture) - Active leak beneath both sink in 11260 upstairs bath
(5) Slow drain at left sink.  Recommend cleaning to restore proper drainage.  If this does not correct, contract plumber to investigate and repair to avoid possible overflow.  No associated damages visible during time of inspection.
7.10 VANITY, CABINETRY, AND COUNTERTOPS
Comments: Inspected. Appears Good Or In Working Condition.
7.11 TOILET
Comments: Maintenance Item.
(1) 11262 - Upstairs toilet is loose and leaking.  Recommend properly repairing to avoid future damages to underlying framing members.  Unable to determine extent of underlying damages during time of inspection.
7.11 Item 1(Picture) - Leakage at 11262 upstairs toilet
(2) 11262/11266/12258 - Half bath toilet is loose.  This condition will eventually worsen and leak if not repaired.  Recommend properly securing to avoid future leakage and associated damages.  None visible during time of inspection.
(3) 11266/11264/11260/11258/11256 - Upstairs toilet is loose.  This condition will eventually worsen and leak if not repaired.  Recommend properly securing to avoid future leakage and associated damages.  None visible during time of inspection.
(4) 11264 - Toilet flush handle is broken in half bath.  Recommend repairing to restore proper operation. 
(5) 11260 - Half bath toilet is loose and leaking.  Recommend properly repairing to avoid further leakage and associated moisture damages.  Unable to determine extent of underlying damages during time of inspection.
7.12 TUB AND ENCLOSURE
Comments: Maintenance Item.
(1) 11262 - Loose shower head piping and faucet in upstairs bath.  Recommend properly securing to avoid possible leakage due to movement.  None visible during time of inspection.
(2) 11262 - Tub faucet is leaking.  Recommend repairing to restore proper operation. 
(3) 11264 - Deteriorated caulking at base of tub enclosure.  Recommend properly recaulking to reduce possible moisture penetration and associated damages. None visible during time of inspection.
7.12 Item 1(Picture) - Deteriorated caulking at base of 11264 tub enclosure
(4) 11260/11256 - Loose shower head piping.  Recommend properly securing to avoid possible leakage due to movement.  None visible during time of inspection.
(5) 11258 - Faucet diverter is stuck closed (only shower works).  Recommend repairing to restore proper operation. 
7.13 HEAT SOURCE
Comments: Inspected. Appears Good Or In Working Condition.
Top Table of Contents Bottom
8.  COMMON AREAS
Styles & Materials
Floor:
CARPET
TILE
WOOD
Walls:
DRYWALL
Ceiling:
DRYWALL
Windows:
ALUMINUM
SINGLE HUNG
Stairway / Railing:
CARPET
METAL RAILING
Front Door:
METAL CLAD
DEADBOLT
Items
8.0 FLOORS
Comments: Inspected. Appears Good Or In Working Condition.
8.1 WALLS
Comments: Inspected. Appears Good Or In Working Condition.
8.2 CEILINGS
Comments: Inspected. Appears Good Or In Working Condition.
8.3 WINDOWS
Comments: Inspected. Appears Good Or In Working Condition.
8.4 LIGHTING
Comments: Inspected. Appears Good Or In Working Condition.
8.5 RECEPTACLES AND SWITCHES
Comments: Inspected. Appears Good Or In Working Condition.
8.6 STAIRWAY AND RAILING
Comments: Inspected. Appears Good Or In Working Condition.
8.7 FRONT DOOR
Comments: Maintenance Item.
11266 - Deteriorated weatherstripping around front door.  Recommend repairing to reduce possible moisture penetration and increase energy efficiency to space.
8.7 Item 1(Picture) - Deteriorated caulking around 11266 front door
8.8 SMOKE/CO DETECTORS
Comments: Safety Item.
11258/11256 - Smoke detector missing in upstairs hallway.   Installation necessary to provide necessary early fire/smoke detection to space.
Top Table of Contents Bottom
9.  KITCHEN AND COMPONENTS
Styles & Materials
Floor Covering:
TILE
WOOD
Walls:
DRYWALL
Ceiling:
DRYWALL
Windows:
ALUMINUM
SINGLE HUNG
SLIDING
Cabinetry:
WOOD
Countertop:
LAMINATE
Patio Door:
METAL
VINYL
SLIDING
Disposer:
BADGER
Dishwasher:
WHIRLPOOL
Range / Oven / Cooktop:
WHIRLPOOL
Exhaust / Range Hood:
BROAN
Refrigerator:
HOTPOINT
GFCI Protection:
IN SAME SPACE
   
Items
9.0 FLOOR
Comments: Inspected. Appears Good Or In Working Condition.
9.1 WALLS
Comments: Inspected. Appears Good Or In Working Condition.
9.2 CEILING
Comments: Specialist Item.
11262 - Moisture stains and damages visible at ceiling.  This appears to be caused from active leakage at toilet in hall bath, above.  Recommend hiring professional roofing contractor to investigate and repair to avoid continued moisture damages.  Unable to determine extent of underlying damages during time of inspection.
9.2 Item 1(Picture) - Active leakage in 11262 kitchen ceiling
9.3 WINDOWS
Comments: Inspected. Appears Good Or In Working Condition.
9.4 PATIO DOOR
Comments: Inspected. Appears Good Or In Working Condition.
9.5 LIGHTING
Comments: Inspected. Appears Good Or In Working Condition.
9.6 CEILING FAN
Comments: Inspected. Appears Good Or In Working Condition.
9.7 RECEPTACLES AND SWITCHES
Comments: Safety Item.
11264/11260/11256 - No GFCI protection to the left of sink.  Recommend installing to provide necessary electrical safety protection to circuit. 
9.8 SINK, FAUCET, PLUMBING, AND TRAP DRAIN
Comments: Maintenance Item.
11264 - Active leakage beneath sink.  Recommend properly repairing to avoid further leakage and associated moisture damages.  No significant damages visible during time of inspection.
9.8 Item 1(Picture) - Active leakage beneath 11264 kitchen sink
9.9 CABINETS AND COUNTERTOPS
Comments: Inspected. Appears Good Or In Working Condition.
9.10 FOOD WASTE DISPOSER
Comments: Inspected. Appears Good Or In Working Condition.
9.11 DISHWASHER
Comments: Inspected. Appears Good Or In Working Condition.
9.12 STOVE/OVEN/COOKTOP
Comments: Inspected. Appears Good Or In Working Condition.
9.13 RANGE HOOD
Comments: Maintenance Item.
11264/11260 - Light is out.  Replace bulb.  If this does not correct, recommend contracting electrician to investigate and repair as necessary to restore proper operation.
9.14 REFRIGERATOR
Comments: Inspected. Appears Good Or In Working Condition.
9.15 HEAT SOURCE
Comments: Inspected. Appears Good Or In Working Condition.
9.16 SMOKE/CO DETECTOR
Comments: Not Present.
Top Table of Contents Bottom
10.  LIVING ROOM
Styles & Materials
Floor:
CARPET
Walls:
DRYWALL
Ceiling:
DRYWALL
Windows:
ALUMINUM
SINGLE HUNG
SLIDING
Patio Door:
METAL
SLIDING
 
Items
10.0 FLOOR
Comments: Inspected. Appears Good Or In Working Condition.
10.1 WALLS
Comments: Inspected. Appears Good Or In Working Condition.
10.2 CEILING
Comments: Inspected. Appears Good Or In Working Condition.
10.3 WINDOWS
Comments: Inspected. Appears Good Or In Working Condition.
10.4 PATIO DOOR
Comments: Maintenance Item.
11266 - Active leakage around patio door.  Recommend hiring professional contractor to evaluate and repair to maintain proper performance. Unable to determine extent of underlying damages during time of inspection.
10.5 LIGHTING
Comments: Not Present.
10.6 RECEPTACLES AND SWITCHES
Comments: Inspected. Appears Good Or In Working Condition.
10.7 HEAT SOURCE
Comments: Inspected. Appears Good Or In Working Condition.
10.8 SMOKE/CO DETECTORS
Comments: Not Present.
Top Table of Contents Bottom
11.  DINING ROOM
Styles & Materials
Floor:
WOOD
Walls:
DRYWALL
Ceiling:
DRYWALL
Patio Door:
VINYL
SLIDING
   
Items
11.0 FLOOR
Comments: Inspected. Appears Good Or In Working Condition.
11.1 WALLS
Comments: Inspected. Appears Good Or In Working Condition.
11.2 CEILING
Comments: Inspected. Appears Good Or In Working Condition.
11.3 PATIO DOOR
Comments: Inspected. Appears Good Or In Working Condition.
11.4 LIGHTING
Comments: Maintenance Item.
11266 - Light out. Replace bulb.  If this does not correct, recommend contracting electrician to investigate and correct to restore safe and proper operation.
11.5 CEILING FAN
Comments: Inspected. Appears Good Or In Working Condition.
11.6 RECEPTACLES AND SWITCHES
Comments: Inspected. Appears Good Or In Working Condition.
11.7 HEAT SOURCE
Comments: Inspected. Appears Good Or In Working Condition.
11.8 SMOKE/CO DETECTORS
Comments: Not Present.
Top Table of Contents Bottom
12.  BASEMENT/CRAWLSPACE/SUB-BASEMENT
The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the home inspector or other persons.
Styles & Materials
Limitations:
HEAVY CLUTTER AND STORAGE ITEMS
HVAC DUCTING
PLUMBING COMPONENTS
Floor:
CONCRETE
Foundation / Wall:
POURED CONCRETE
Ceiling:
UNFINISHED
Vents / Windows:
ALUMINUM
SLIDING
Columns / Beams / Posts:
METAL BEAM
METAL POST
Rim / Floor Joists:
WOOD
   
Items
12.0 BASEMENT STAIRWAY AND RAILING
Comments: Safety Item.
11264 - Missing handrail at basement steps.  Recommend installing to provide necessary stability during use. 
12.0 Item 1(Picture) - Missing handrail at 11264 basement steps
12.1 FLOOR
Comments: Inspected. Appears Good Or In Working Condition.
12.2 FOUNDATION / WALLS
Comments: Specialist Item.
(1) 11266 - Settlement cracking visible on East side of basement.  Previous repairs do not appear to have been successful since subsequent movement is visible.  Recommend hiring professional foundation contractor to properly repoint to avoid further deterioration and possible moisture seepage.  None visible during time of inspection.
12.2 Item 1(Picture) - Settlement crack in 11266 foundation wall
(2) 11256 - Superficial mold visible on wall.  This is likely due to basement bring dark and dryer venting into space.  Recommend cleaning wall and installing dehumidifier within basement to avoid associated health hazards.  No moisture damages visible during time of inspection.
12.2 Item 2(Picture) - Mold on walls in 11256 basement
12.2 Item 3(Picture) - More mold in 11256 basement
12.2 Item 4(Picture) - And more superficial mold in 11256 basement
12.3 CEILING / SUB-FLOOR
Comments: Specialist Item.
(1) 11260 - Moisture damages visible at sub-floor beneath half bath toilet.  Recommend hiring professional contractor to evaluate and repair to avoid further leakage and associated damages.  No significant damages visible during time of inspection.
12.3 Item 1(Picture) - Active leakage beneath 11260 half bath toilet
(2) 11260 - Daylight visible through sub floor on South side of basement.  Recommend hiring professional contractor to investigate and repair to avoid continued damage to underlying framing members.  No significant damages visible during time of inspection. 
12.3 Item 2(Picture) - Daylight through 11260 rim joist
12.4 RIM/FLOOR JOISTS
Comments: Inspected. Appears Good Or In Working Condition.
12.5 VENTS OR WINDOWS
Comments: Inspected. Appears Good Or In Working Condition.
12.6 DOORS
Comments: Inspected. Appears Good Or In Working Condition.
12.7 LIGHTING
Comments: Inspected. Appears Good Or In Working Condition.
12.8 RECEPTACLES AND SWITCHES
Comments: Inspected. Appears Good Or In Working Condition.
12.9 CIRCUIT WIRING
Comments: Inspected. Appears Good Or In Working Condition.
12.10 COLUMNS, BEAMS, OR POSTS
Comments: Inspected. Appears Good Or In Working Condition.
12.11 HEAT SOURCE
Comments: Inspected. Appears Good Or In Working Condition.
12.12 SMOKE / CO DETECTORS
Comments: Safety Item.
11256 - Smoke detector missing.   Installation necessary to provide necessary early fire/smoke detection to space.
The structure of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
13.  LAUNDRY
Styles & Materials
Floor:
VINYL
Walls:
DRYWALL
Ceiling:
DRYWALL
Dryer Energy Source:
220V 3-PRONG
Dryer Vent Termination:
EXTERIOR
 
Items
13.0 FLOOR
Comments: Inspected. Appears Good Or In Working Condition.
13.1 WALLS
Comments: Inspected. Appears Good Or In Working Condition.
13.2 CEILING
Comments: Inspected. Appears Good Or In Working Condition.
13.3 LIGHTING
Comments: Inspected. Appears Good Or In Working Condition.
13.4 RECEPTACLES AND SWITCHES
Comments: Inspected. Appears Good Or In Working Condition.
13.5 TRAP/DRAIN
Comments: Inspected. Appears Good Or In Working Condition.
13.6 HEAT SOURCE
Comments: Inspected. Appears Good Or In Working Condition.
13.7 SMOKE DETECTOR
Comments: Not Present.
Top Table of Contents Bottom
14.  CENTRAL HEATING
The home inspector shall observe permanently installed heating systems including: Heating equipment; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The home inspector shall describe: Energy source; and Heating equipment and distribution type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms.
11266
Styles & Materials
Location of Thermostat:
HALLWAY
Heat Type:
FORCED AIR
Fuel Source:
NATURAL GAS
Filter Type:
DISPOSABLE
Heating Unit Manufacturer:
INTERTHERM
NORDYNE
RHEEM
WEATHERKING
Heating Unit Age:
12
13
20
Input BTUH:
72000
75000
96000
   
Items
14.0 ENERGY SOURCE
Comments: Inspected. Appears Good Or In Working Condition.
14.1 HEATING EQUIPMENT
Comments: Maintenance Item.
(1) 11262/11260/11256 - Furnace is 20 years old (expected life is 20-25 years) and displays heavy rust and corrosion in burner/heat exchanger areas.  Unable to determine extent of underlying damages, but unit performs as intended during time of inspection.  Recommend having unit serviced regularly to maximize life and system efficiency.  Budget for future replacement.
14.1 Item 1(Picture) - Rust and corrosion in 11262 furnace
14.1 Item 2(Picture) - Rust and corrosion inside 11260 furnace
14.1 Item 3(Picture) - Rust and corrosion inside 11256 furnace
(2) 11258 - Furnace is 37 years old (expected life is 20-25 years) and displays heavy rust, corrosion, and sediment build-up in burner/blower/heat exchanger areas.  Unable to determine extent of underlying damages, but unit performs as intended during time of inspection.  Recommend having unit serviced regularly to maximize life and system efficiency.  Budget for future replacement.
14.1 Item 4(Picture) - View inside 11258 furnace
14.2 NORMAL OPERATING CONTROLS
Comments: Inspected. Appears Good Or In Working Condition.
14.3 AUTOMATIC SAFETY CONTROLS
Comments: Inspected. Appears Good Or In Working Condition.
14.4 CHIMNEYS, FLUES AND VENTS
Comments: Maintenance Item.
(1) 11262 - HVAC supply vent is disconnected within basement.  Recommend properly sealing with metallic tape to maximize system efficiency.
14.4 Item 1(Picture) - Vent disconnected inside 11262 basement
(2) 11262 - Duct tape used to seal seams at HVAC vents.  This is improper and tape will ultimately become dry and brittle.  Recommend properly sealing all open seams with metal tape then properly insulating ducting to maximize flow and efficiency to home.
14.4 Item 2(Picture) - Duct tape at vents in 11262 basement
(3) 11266 - Open seams at HVAC exhaust vent above furnace.  This is a health hazard since dangerous flue gases can escape into home. Recommend properly sealing all open seams with metal tape to maximize draw and maintain safe furnace operation. 
14.4 Item 3(Picture) - Open seams at 11266 furnace exhaust vent
14.5 HEAT DISTRIBUTION SYSTEM
Comments: Inspected. Appears Good Or In Working Condition.
14.6 HEAT SOURCE IN EACH LIVING SPACE
Comments: Inspected. Appears Good Or In Working Condition.
14.7 SMOKE/CO DETECTORS IN SPACE
Comments: Safety Item.
11262/11266/11264/11260/11258/11256 - No CO detector present in rooms with fuel burning appliances.  A CO detector should be installed in same space as all fuel-burning appliances (not directly above or beside units since it is normal for them to emit a small amount of carbon monoxide upon start-up) and in all upper-level hallways.   Recommend installing to provide early CO detection to occupants and avoid associated personal safety hazards
14.8 FURNACE ENCLOSURE
Comments: Maintenance Item.
11262/11264/11260 - Air leaks at seams around furnace enclosure.  This is inefficient.  Recommend sealing all leaks with metallic tape to maximize system efficiency and improve performance.
14.8 Item 1(Picture) - Air leaks around 11262 furnace enclosure
14.8 Item 2(Picture) - Air leaks around 11264 furnace enclosure
14.8 Item 3(Picture) - Air leak at 11260 refrigerant lines
The heating system of this home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
15.  PLUMBING SYSTEM
The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials.
Styles & Materials
Water Main Location:
BASEMENT
Water Source:
PUBLIC
Hose Bibs:
FROST FREE
Plumbing Service:
COPPER
Plumbing Distribution:
COPPER
Plumbing Waste:
PVC
Water Heater Manufacturer:
A.O. SMITH
U.S. CRAFTMASTER
WHIRLPOOL
Water Heater:
NATURAL GAS
40 GAL. (1-2 PEOPLE)
Water Heater Age:
10
12
13
17
Items
15.0 MAIN WATER SUPPLY
Comments: Specialist Item.
11256 - Active leakage in pressure reducing valve.  Recommend contracting plumber to evaluate and repair to avoid continued leakage and possible moisture damage.  None visible during time of inspection.
15.0 Item 1(Picture) - Active leak at 11256 pressure reducing valve
15.1 MAIN WATER SHUT-OFF
Comments: Maintenance Item.
11262/11260 - Active leakage in water main valve.  Recommend contracting professional plumber to evaluate and repair to avoid continued leakage and possible moisture damage.  None visible during time of inspection.
15.1 Item 1(Picture) - Active leakage at 11262 water main
15.1 Item 2(Picture) - Active leakage at 11260 water main
15.2 HOSE BIBS
Comments: Inspected. Appears Good Or In Working Condition.
15.3 DISTRIBUTION PIPING
Comments: Specialist Item.
11262 - Copper plumbing is in contact with galvanized HVAC ducting.  This will lead to galvanic corrosion and leakage. Recommend contracting professional plumber to evaluate and relocate to avoid possible moisture damages.  None visible during time of inspection.
15.3 Item 1(Picture) - Water lines touch galvanized ducting in 11262 basement
15.4 INTERIOR DRAIN, WASTE AND VENT SYSTEMS
Comments: Inspected. Appears Good Or In Working Condition.
15.5 FUEL DISTRIBUTION SYSTEMS
Comments: Specialist Item.
11260 - No dirt leg present on natural gas supply line to water heater.  This is piping component is necessary to keep natural gas clean and extend life of associated gas appliances.  Recommend installing to maximize useful life.  See attached photo at bottom of report for a detailed view.
15.5 Item 1(Picture) - No dirt leg at 11260 water heater
15.6 WATER HEATER
Comments: Maintenance Item.
(1) 11262/11266/11264/11260/11258/11256 - Active leakage at drip tube.  This can be caused by high tank pressure or sediment beneath valve seat.  Recommend contracting professional plumber to evaluate and repair to restore proper performance.  No associated damages visible during time of inspection.
15.6 Item 1(Picture) - Active leak at 11262 water heater relief valve
15.6 Item 2(Picture) - Active leak at 11266 relief valve
15.6 Item 3(Picture) - Active leak at 11264 relief valve
15.6 Item 4(Picture) - Active leak at 11260 relief valve
15.6 Item 5(Picture) - Active leak at 11258 relief valve
(2) 11262/11258 - Rust and corrosion in and around water heater.  Units are 13 & 8 years old and operate as intended during time of inspection.  These conditions and its age (typical life of water heater is 10-12 years) indicate unit is at the end of its useful life.  Budget for replacement.
15.6 Item 6(Picture) - Rust at base of 11262 water heater
15.6 Item 7(Picture) - Corrosion on top of 11258 water heater
(3) 11262 - Glass view port is broken.  This will affect water heater efficiency and performance.  Recommend hiring professional plumber to evaluate and repair to restore safe and proper operation.
15.6 Item 8(Picture) - Broken glass at 11262 water heater
(4) 11266 - Rust and corrosion in and around water heater.  Unit is 17 years old and operates as intended during time of inspection.  These conditions and its age (typical life of water heater is 10-12 years) indicate unit is at the end of its useful life.  Budget to replace.
15.6 Item 9(Picture) - Rust around 11266 water heater
(5) 11260 - Active leakage at drain bibb.  Recommend hiring professional plumber to evaluate and repair to reduce continued leakage and associated moisture damages.  Moisture damages visible during time of inspection.
15.6 Item 10(Picture) - Active leakage at 11260 drain bibb
The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within the pipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
16.  ELECTRICAL SYSTEMS
The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment.
11262
Styles & Materials
Electrical Service:
UNDERGROUND
ALUMINUM SERVICE CONDUCTORS
220 VOLTS
Service Size:
100 AMP
Circuit Protection:
CIRCUIT BREAKERS
Main Panel Manufacturer:
ZINSCO
Conductor Materials:
COPPER
ROMEX
Grounding:
WATER MAIN
Items
16.0 SERVICE ENTRANCE
Comments: Specialist Item.
11256/11260 - Electrical service meter is pulling away from home.  This is likely caused by grading settlement. Recommend contract local utility to properly evaluate and repair to maintain reliable service and avoid possible damage.  No significant damages visible during time of inspection.
16.0 Item 1(Picture) - Loose meter at 11256
16.0 Item 2(Picture) - Loose meter at 11260
16.1 DISTRIBUTION PANEL
Comments: Maintenance Item.
(1) 11262/11266/11264/11260/11258/11256 - Zinsco main distribution panel installed.  These panels were originally made in Puerto Rico and installed in the 60's and 70's throughout the USA.  There are many still in use in both single-family and multi-family units.  Zinsco sold their manufacturing plants to Sylvania who then marketed them under the GTE Sylvania brand until finally closing down.  Today, the Zinsco name is owned by Thomas and Betts. 

Major Problems: 

1) It has been found that circuit breakers do not trip under normal overload conditions (It has been known to sometimes take up to 60-amps to trip a 15-amp Zinsco breaker. 

2) The parallel flat buss bars are made of aluminum material and corrode quite easily, increasing the electrical resistance at point of contact and causing panels to overheat. 

3) The plating that coats the buss bars sometimes fails on many Zinsco panels, causing poor circuit breaker connections. 

4) Another problem is that the breakers do not have designated positions, i.e., they can slide up and down the buss bar, are often crooked, and it is not uncommon to see gaps between the breakers with the deadfront cover in place. 

Recommend monitoring panel for signs of overheating.  No signs of past problems visible during time of inspection.

16.1 Item 1(Picture) - This is a Zinsco panel
(2) 11262 - 15-Amp circuit breaker in main panel would not reset (unable to turn breaker on) during time of inspection.  Recommend contracting electrician to investigate and repair to restore proper operation.  Unable to pinpoint cause during time of inspection.
16.1 Item 2(Picture) - Breaker will not reset in 11262 panel
(3) 11262/11266 - Knockout missing.  These are necessary to maintain designed electrical safety and avoid rodent intrusion.  Recommend contracting electrician to install and avoid associated electrical safety hazards.
16.1 Item 3(Picture) - Missing knockout at 11262 panel
16.1 Item 4(Picture) - Missing knockout at 11266 panel
(4) 11264/11256 - Double tapping present (2 circuits double tapped).  This presents a possible overheating hazard.  Contract professional electrician to evaluate and correct to avoid associated electrical safety hazards and maintain proper system performance.  No associated damages visible during time of inspection.
16.1 Item 5(Picture) - Double tapped breaker inside 11264 panel
16.1 Item 6(Picture) - Double tapped breaker inside 11256 panel
(5) 11258 - Twistout missing.  These are necessary to maintain designed electrical safety and avoid rodent intrusion.  Recommend contracting electrician to install and avoid associated electrical safety hazards.
16.1 Item 7(Picture) - Missing twistout in 11258 panel
16.2 CIRCUIT WIRING
Comments: Inspected. Appears Good Or In Working Condition.
16.3 GROUNDING
Comments: Specialist Item.
11266/11260/11256 - No main grounding conductor installed.  Installation necessary to maintain electrical grounding protection to home.  Contract licensed electrician to properly correct and restore electrical safety to system and occupants.
The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.